Warning Icon
This product will be discontinued on: December 31, 2024

For other alternatives, please contact us for more information.

0 Replacement products available

E15R02P27

Tower Mounted Amplifier, Dual 700 MHz with AISG 2.0

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.
Features and Benefits
  • TMA is operating in AISG & CWA mode, Alarm Current consumption CWA mode 190 mA
  • Designed to boost UP-Link Coverage and KPIs
  • RET interface to control antenna RET actuators with AISG standard
  • Single AISG with 1 RET connector
  • Automatic LNA by-pass function
  • Built in lightning protection
  • Connectors “in line”
  • 2 input ports and 2 output ports

Product Classification

Product Type 1-BTS:1-ANT (Uniplex) | Tower mounted amplifier

General Specifications

Color Gray
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 7-16 DIN Female

Dimensions

Height 144 mm | 5.669 in
Width 230 mm | 9.055 in
Depth 320 mm | 12.598 in
Ground Screw Diameter 8 mm | 0.315 in
Mounting Pipe Diameter Range 40–160 mm

Outline Drawing

Click on image to enlarge.

Electrical Specifications

License Band, LNA APT 700 | DCS 1800

Electrical Specifications, dc Power/Alarm

dc Switching/Redundancy Yes
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform
Operating Current at Voltage 110 mA @ 12 V
Operating Current Tolerance ±20 mA
Voltage, CWA Mode 7–18 Vdc
Alarm Current, CWA Mode 190 mA ±10 mA

Electrical Specifications, AISG

AISG Connector 8-pin DIN Female
AISG Connector Standard IEC 60130-9
Protocol AISG 2.0
Voltage, AISG Mode 7–30 Vdc

Electrical Specifications

Sub-module 1 | 2
Branch 1
Port Designation ANT
License Band APT 700, LNA

Electrical Specifications, Rx Uplink

Frequency Range, MHz 703–748
Bandwidth, MHz 45.00
Gain, nominal, dB 13.0
Gain Tolerance, dB ±1
Noise Figure, maximum, dB 2.0
Noise Figure, typical, dB 1.2
Group Delay Variation, maximum, ns 100
Group Delay Variation Bandwidth, MHz 5.00
Total Group Delay, maximum, ns 150
Return Loss, minimum, dB 18
Return Loss, typical, dB 20
Insertion Loss - Bypass Mode, typical, dB 1.3
Return Loss - Bypass Mode, typical, dB 18

Electrical Specifications, Tx Downlink

Frequency Range, MHz 758–803
Bandwidth, MHz 45.00
Insertion Loss, maximum, dB 0.50
Insertion Loss, typical, dB 0.40
Group Delay Variation, maximum, ns 30
Group Delay Variation Bandwidth, MHz 5.00
Return Loss, minimum, dB 18
Return Loss, typical, dB 20
Input Power, RMS, maximum, W 200
Input Power, PEP, maximum, W 2,500
3rd Order PIM, typical, dBc -153
3rd Order PIM Test Method Two +43 dBm carriers

Block Diagram

Click on image to enlarge.

Material Specifications

Finish Painted

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Volume 10 L
Weight, net 12 kg | 26.455 lb

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Classification

Product Type 1-BTS:1-ANT (Uniplex) | Tower mounted amplifier

General Specifications

Color Gray
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 7-16 DIN Female

Dimensions

Height 144 mm | 5.669 in
Width 230 mm | 9.055 in
Depth 320 mm | 12.598 in
Ground Screw Diameter 8 mm | 0.315 in
Mounting Pipe Diameter Range 40–160 mm

Electrical Specifications

License Band, LNA APT 700 | DCS 1800

Electrical Specifications, dc Power/Alarm

dc Switching/Redundancy Yes
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform
Operating Current at Voltage 110 mA @ 12 V
Operating Current Tolerance ±20 mA
Voltage, CWA Mode 7–18 Vdc
Alarm Current, CWA Mode 190 mA ±10 mA

Electrical Specifications, AISG

AISG Connector 8-pin DIN Female
AISG Connector Standard IEC 60130-9
Protocol AISG 2.0
Voltage, AISG Mode 7–30 Vdc

Electrical Specifications

Sub-module 1 | 2
Branch 1
Port Designation ANT
License Band APT 700, LNA

Electrical Specifications, Rx Uplink

Frequency Range, MHz 703–748
Bandwidth, MHz 45.00
Gain, nominal, dB 13.0
Gain Tolerance, dB ±1
Noise Figure, maximum, dB 2.0
Noise Figure, typical, dB 1.2
Group Delay Variation, maximum, ns 100
Group Delay Variation Bandwidth, MHz 5.00
Total Group Delay, maximum, ns 150
Return Loss, minimum, dB 18
Return Loss, typical, dB 20
Insertion Loss - Bypass Mode, typical, dB 1.3
Return Loss - Bypass Mode, typical, dB 18

Electrical Specifications, Tx Downlink

Frequency Range, MHz 758–803
Bandwidth, MHz 45.00
Insertion Loss, maximum, dB 0.50
Insertion Loss, typical, dB 0.40
Group Delay Variation, maximum, ns 30
Group Delay Variation Bandwidth, MHz 5.00
Return Loss, minimum, dB 18
Return Loss, typical, dB 20
Input Power, RMS, maximum, W 200
Input Power, PEP, maximum, W 2,500
3rd Order PIM, typical, dBc -153
3rd Order PIM Test Method Two +43 dBm carriers

Material Specifications

Finish Painted

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Volume 10 L
Weight, net 12 kg | 26.455 lb
Click on image to enlarge.
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence