CTX41727T-DS-43 | E14F10P52

Twin Triplexer 380-960/1695-2200/2300- 2700, DC-sense with 4.3-10 connectors

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.
Features and Benefits
  • BTS-to-feeder and feeder-to-antenna application
  • Automatic dc switching with dc sense
  • New 4.3-10 connectors for improved PIM performance and size reduction
  • DC Load Sense in Feeder-to-Antenna applications
  • Convertible mounting brackets
  • Stackable in multiples with included hardware

Product Classification

Product Type Triplexer

General Specifications

Product Family CTX41727
Color Gray
Common Port Label COMM
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 4.3-10 Female
RF Connector Interface Body Style Long neck

Dimensions

Height 160 mm | 6.299 in
Width 165 mm | 6.496 in
Depth 108 mm | 4.252 in
Ground Screw Diameter 6 mm | 0.236 in
Mounting Pipe Diameter Range 42.6–122 mm

Outline Drawing

Click on image to enlarge.

Electrical Specifications

Impedance 50 ohm
License Band, Band Pass APT 700 | AWS 1700 | CEL 850 | CEL 900 | DCS 1800 | EDD 800 | IMT 2100 | IMT 2600 | LMR 750 | LMR 800 | LMR 900 | PCS 1900 | USA 700 | USA 750 | WCS 2300

Electrical Specifications, dc Power/Alarm

dc/AISG Pass-through Method Auto sensing
dc/AISG Pass-through Path See logic table
Lightning Surge Current 5 kA
Lightning Surge Current Waveform 8/20 waveform
Voltage 7–32 Vdc

Electrical Specifications

Sub-module 1 | 2 1 | 2 1 | 2
Branch 1 2 3
Port Designation 380-960 1695-2200 2300-2700
License Band CEL 850, Band Pass
CEL 900, Band Pass
USA 700, Band Pass
USA 750, Band Pass
AWS 1700, Band Pass
DCS 1800, Band Pass
IMT 2100, Band Pass
PCS 1900, Band Pass
IMT 2600, Band Pass
WCS 2300, Band Pass

Electrical Specifications, Band Pass

Frequency Range, MHz 380–960 1695–2200 (12) 2300–2700
Insertion Loss, typical, dB 0.10 0.20 0.20
Total Group Delay, maximum, ns 20 25 25
Return Loss, typical, dB 20 20 20
Isolation, minimum, dB 50 50 50
Input Power, RMS, maximum, W 200 200 200
Input Power, PEP, maximum, W 2,000 2,000 2,000
3rd Order PIM, maximum, dBc -155 -155 -155
3rd Order PIM Test Method Two +43 dBm carriers Two +43 dBm carriers Two +43 dBm carriers

Block Diagram

Click on image to enlarge.

Logic Table

Click on image to enlarge.

Mechanical Specifications

Wind Loading @ Velocity, frontal 36.0 N @ 150 km/h (8.1 lbf @ 150 km/h)
Wind Loading @ Velocity, lateral 17.0 N @ 150 km/h (3.8 lbf @ 150 km/h)

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Volume 2.8 L
Weight, without mounting hardware 4.7 kg | 10.362 lb

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant/Exempted
CHINA-ROHS Above maximum concentration value
UK-ROHS Compliant/Exempted

Product Classification

Product Type Triplexer

General Specifications

Product Family CTX41727
Color Gray
Common Port Label COMM
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 4.3-10 Female
RF Connector Interface Body Style Long neck

Dimensions

Height 160 mm | 6.299 in
Width 165 mm | 6.496 in
Depth 108 mm | 4.252 in
Ground Screw Diameter 6 mm | 0.236 in
Mounting Pipe Diameter Range 42.6–122 mm

Electrical Specifications

Impedance 50 ohm
License Band, Band Pass APT 700 | AWS 1700 | CEL 850 | CEL 900 | DCS 1800 | EDD 800 | IMT 2100 | IMT 2600 | LMR 750 | LMR 800 | LMR 900 | PCS 1900 | USA 700 | USA 750 | WCS 2300

Electrical Specifications, dc Power/Alarm

dc/AISG Pass-through Method Auto sensing
dc/AISG Pass-through Path See logic table
Lightning Surge Current 5 kA
Lightning Surge Current Waveform 8/20 waveform
Voltage 7–32 Vdc

Electrical Specifications

Sub-module 1 | 2 1 | 2 1 | 2
Branch 1 2 3
Port Designation 380-960 1695-2200 2300-2700
License Band CEL 850, Band Pass; CEL 900, Band Pass; USA 700, Band Pass; USA 750, Band Pass AWS 1700, Band Pass; DCS 1800, Band Pass; IMT 2100, Band Pass; PCS 1900, Band Pass IMT 2600, Band Pass; WCS 2300, Band Pass

Electrical Specifications, Band Pass

Frequency Range, MHz 380–960 1695–2200 (12) 2300–2700
Insertion Loss, typical, dB 0.10 0.20 0.20
Total Group Delay, maximum, ns 20 25 25
Return Loss, typical, dB 20 20 20
Isolation, minimum, dB 50 50 50
Input Power, RMS, maximum, W 200 200 200
Input Power, PEP, maximum, W 2,000 2,000 2,000
3rd Order PIM, maximum, dBc -155 -155 -155
3rd Order PIM Test Method Two +43 dBm carriers Two +43 dBm carriers Two +43 dBm carriers

Mechanical Specifications

Wind Loading @ Velocity, frontal 36.0 N @ 150 km/h (8.1 lbf @ 150 km/h)
Wind Loading @ Velocity, lateral 17.0 N @ 150 km/h (3.8 lbf @ 150 km/h)

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Volume 2.8 L
Weight, without mounting hardware 4.7 kg | 10.362 lb
Click on image to enlarge.
Click on image to enlarge.
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant/Exempted
CHINA-ROHS Above maximum concentration value
UK-ROHS Compliant/Exempted

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence