Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

RCT6-S-1A-RNA

RCT6, RADIAX® Coaxial Radiating Cable with Bump, 1700-2500 MHz, tuned foil, 1-1/4 in, black non-halogenated, fire retardant polyolefin jacket

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Product Type Radiating cable
Product Brand RADIAX®
Product Series RCT6

General Specifications

Polarization Vertical
Cable Type Radiating Mode (RCT) Series
Jacket Color Black

Dimensions

Diameter Over Jacket, maximum 39.116 mm | 1.54 in
Inner Conductor OD 14.208 mm | 0.559 in
Outer Conductor OD 34.036 mm | 1.34 in
Nominal Size 1-1/4 in
Recommended Distance from the Wall 101.6 mm | 4 in
Recommended Hanger Spacing 1.3 m | 4.265 ft

Electrical Specifications

Attenuation Test Method IEC 61196-4
Attenuation Tolerance ±5%
Cable Impedance 50 ohm ±2 ohm
dc Resistance, Inner Conductor 1.74 ohms/km | 0.53 ohms/kft
dc Resistance, Outer Conductor 2.953 ohms/km | 0.9 ohms/kft
dc Test Voltage 8500 V
Insulation Resistance 100000 MOhms-km
Jacket Spark Test Voltage (rms) 10000 V
Operating Frequency Band 1700 – 2500 MHz
Optimum Operating Frequency Band 2300 – 2500 MHz
Peak Power 180 kW
Velocity 91 %
VSWR Installed, typical, 1700–2500 MHz 1.2999999523162842
VSWR on Reel, typical 1.4299999475479126

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) Coupling Loss 50% Coupling Loss 95%
1700.0 MHz 3.500 1.066 75 77
1800.0 MHz 3.600 1.097 72 76
1900.0 MHz 3.800 1.158 70 72
2000.0 MHz 3.900 1.188 69 73
2100.0 MHz 4.100 1.250 67 70
2200.0 MHz 4.300 1.310 67 70
2300.0 MHz 4.500 1.370 66 69
2400.0 MHz 4.800 1.463 63 66
2500.0 MHz 5.200 1.584 62 65

Material Specifications

Dielectric Material Foam PE
Jacket Material Non-halogenated, fire retardant polyolefin
Inner Conductor Material Corrugated copper tube
Outer Conductor Material Copper foil

Mechanical Specifications

Minimum Bend Radius, Single Bend 381 mm | 15 in
Tensile Strength 168 kg | 370.376 lb
Bending Moment 15.5 N-m | 137.187 in lb
Coupling Loss Test Method IEC 61196-4
Coupling Loss Tolerance ±5 dB
Flat Plate Crush Strength 1.4 kg/mm | 78.396 lb/in
Indication of Slot Alignment Yes–bumps face the wall

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Storage Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Average Power, Inner Conductor Temperature 100 °C | 212 °F
Fire Retardancy Test Method IEC 60332-1-2 | IEC 60332-3C-24
Smoke Index Test Method IEC 61034
Toxicity Index Test Method IEC 60754-1 | IEC 60754-2

Packaging and Weights

Cable weight 0.64 kg/m | 0.430 lb/ft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Classification

Product Type Radiating cable
Product Brand RADIAX®
Product Series RCT6

General Specifications

Polarization Vertical
Cable Type Radiating Mode (RCT) Series
Jacket Color Black

Dimensions

Diameter Over Jacket, maximum 39.116 mm | 1.54 in
Inner Conductor OD 14.208 mm | 0.559 in
Outer Conductor OD 34.036 mm | 1.34 in
Nominal Size 1-1/4 in
Recommended Distance from the Wall 101.6 mm | 4 in
Recommended Hanger Spacing 1.3 m | 4.265 ft

Electrical Specifications

Attenuation Test Method IEC 61196-4
Attenuation Tolerance ±5%
Cable Impedance 50 ohm ±2 ohm
dc Resistance, Inner Conductor 1.74 ohms/km | 0.53 ohms/kft
dc Resistance, Outer Conductor 2.953 ohms/km | 0.9 ohms/kft
dc Test Voltage 8500 V
Insulation Resistance 100000 MOhms-km
Jacket Spark Test Voltage (rms) 10000 V
Operating Frequency Band 1700 – 2500 MHz
Optimum Operating Frequency Band 2300 – 2500 MHz
Peak Power 180 kW
Velocity 91 %
VSWR Installed, typical, 1700–2500 MHz 1.2999999523162842
VSWR on Reel, typical 1.4299999475479126

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) Coupling Loss 50% Coupling Loss 95%
1700.0 MHz 3.500 1.066 75 77
1800.0 MHz 3.600 1.097 72 76
1900.0 MHz 3.800 1.158 70 72
2000.0 MHz 3.900 1.188 69 73
2100.0 MHz 4.100 1.250 67 70
2200.0 MHz 4.300 1.310 67 70
2300.0 MHz 4.500 1.370 66 69
2400.0 MHz 4.800 1.463 63 66
2500.0 MHz 5.200 1.584 62 65

Material Specifications

Dielectric Material Foam PE
Jacket Material Non-halogenated, fire retardant polyolefin
Inner Conductor Material Corrugated copper tube
Outer Conductor Material Copper foil

Mechanical Specifications

Minimum Bend Radius, Single Bend 381 mm | 15 in
Tensile Strength 168 kg | 370.376 lb
Bending Moment 15.5 N-m | 137.187 in lb
Coupling Loss Test Method IEC 61196-4
Coupling Loss Tolerance ±5 dB
Flat Plate Crush Strength 1.4 kg/mm | 78.396 lb/in
Indication of Slot Alignment Yes–bumps face the wall

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Storage Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Average Power, Inner Conductor Temperature 100 °C | 212 °F
Fire Retardancy Test Method IEC 60332-1-2 | IEC 60332-3C-24
Smoke Index Test Method IEC 61034
Toxicity Index Test Method IEC 60754-1 | IEC 60754-2

Packaging and Weights

Cable weight 0.64 kg/m | 0.430 lb/ft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Specification

Product Specification